Offering you a complete choice of products which include kg645 generator controller kirloskar, genset sedmac controller gc1111, procom econ a and pso 600 cummins genset controller.
₹ 12500 / Piece Get Latest Price
| Power Rating | 125-250 kVA |
| Display Type | LCD |
| Function | Start Stop, Auto Mains Fail |
| Communication Port | RS485, RS232 |
| Country of Origin | Made in India |
| phase | Three |
| Brand | Kiskor |
| Model Name | Kg 645 |
| Usage | Genset controller |
| IP Rating | IP40 |
| Voltage | 12V DC |
| Supply Voltage | 24 V DC |
Established as a Proprietor firm in the year 2021 at Ahmedabad (Gujarat, India), We “Jatin Sales And Service” are a leading Wholesale Trader and Service Provider of a wide range of Relay Card, Genset Controllers, Control Panel, etc.
₹ 7500 / Piece Get Latest Price
| Power Rating | 50-125 kVA |
| Display Type | LCD |
| Function | Auto Mains Fail, Start Stop |
| Communication Port | RS485, RS232 |
| Supply Voltage | 12 V DC |
| Mounting Type | Door Mount |
| Protection Feature | Under Voltage, High Temp, Over Speed, Low Oil, Over Voltage |
| No. of Inputs | 6 Inputs |
| Country of Origin | Made in India |
| PHASE | 3 PHASE |
| Voltage | 415 V AC |
| Frequency | 50 HZ |
| Model Number/Name | GC 1111 |
| Storage Temperature Range | -20 to +80 Degree C |
| CLOUR | BLACK |
| Power Source | 8 VDC TO 35 VDC |
| Brand | SEDMAC MAHINDRA |
| Usage/Application | GENSET APPLICATION |
| KVA RATING | 5 KVA TO 82.5 KVA |
| MAKE | SADMEC |
Minimum order quantity: 1 Piece
The GC 1111 is a compact Auto Mains (Utility) Failure Control Module that has been developed to provide an outstanding range of features within a compact enclosure.
OVERALL SIZE
140 mm x 113 mm x 43 mm (5.5” x 4.4” x 1.5”)
PANEL CUTOUT SIZE
118 mm x 92 mm (4.6" x 3.6")
MAXIMUM PANEL THICKNESS
8.0 mm (0.3”)
WEIGHT
0.28kg
₹ 8850 / Piece Get Latest Price
| Power Rating | 50-125 kVA |
| Phase | Three Phase |
| Display Type | LCD |
| Function | Start Stop, Auto Mains Fail |
| Communication Port | RS485, RS232 |
| Protection Feature | Low Oil, Under Voltage, High Temp, Over Speed, Over Voltage |
| Country of Origin | Made in India |
| Brand | Procom |
| Model No | ECON-A |
| AC Voltage Withstand | 440 VAC (Phase to neutral) |
| Voltages & Current | 1% of Reading |
| Power & Energies | 2% of Reading |
| Surge 1.2/50Usec | 2.5kV |
| Battery Voltage | 9-35 V DC |
| DC Interruption Time | 0.4seconds |
| Cut out Dimensions | 155mm x 117mm |
| Digital Input Level | Battery Voltage (Negative) |
| Depth | 41.8mm |
| Communication | RS232, USB, Modbus on Rs485 (optional) |
| DIGITAL INPUT | 7 DIGITAL INPIT |
| DIGITAL OUTPUT | 8 DIGITAL PUTPUT |
| CONFIGURATION | 3PH MAINS 3PHASE DG , 3PHASE MAINS 1 PHASE DG |
| DISPLAY | DIGITAL DISPALY |
| Voltage | 24V DC |
| Supply Voltage | 12 V DC |
Minimum order quantity: 1 Piece
Product Details:
Auto Mode
ECON-A monitors the Mains supply, if Mains supply varies beyond set limit of under/over voltage or
under/over frequency or voltage unbalance for more than their individual programmed supervision time,
ECON-A releases the MCB contactor (to protect the contactor from failure because of low input voltage)
and attempts to starts the generator after the programmed delay start duration has expired. In case the
mains become healthy during this waiting period the MCB contact is switched on and the crank cycle is
aborted.
In case the heater time is set Heater contact along with Fuel Pump contact is switched on else only the
Fuel Pump contact is switched on.
After 1 second the ECON-A gives cranks the engine by activating the inbuilt, potential free, crank
contact. Crank command is withdrawn if the engine start is detected, either by LLOP pressure or by
build-up of generator voltage, as per the setting done by the user. Max duration of crank command is
user settable.
In case of non-start of the engine ECON-A re-cranks it till it starts or user programmed crank
attempts are exhausted. If generator fails to start after the maximum programmed crank attempts, Fail
to Start LED starts blinking, indicating start failure and the hooter is switched on.
After successful start of the generator, it is allowed to warm up for a user programmed time before the
load is transferred to generator.
While the generator is running ECON-A monitors it for external fault (Digital Inputs: Emergency, VBelt, RWL, user fault 1 and 2) and internal faults (Measured Values faults: LLOP, HWT, Fuel, Over
Load, voltage and frequency).
On persistence of any fault for more than the programmed supervision delay, for that fault, generator
is stopped, corresponding fault is announced & hooter is switched on.
On restoration of healthy mains supply, continuously, for the programmed duration the load is
transferred to the mains and generator is stopped after expiry of re-cooling time. In case mains again
become unhealthy during the re-cooling period the load is switched to generator
ECON-A: It's basically a complete AMF controller and can operate be configured for :
Three Phase Mains Three Phase DG
Three Phase Mains Single Phase DG
Single Phase Mains Single Phase DG
This controller can be operated as Manual controller with provision to control Shunt trip of MCCB:
Single phase with Shunt Trip
Three phase with Shunt Trip
If no shunt trip function is required the controller can be configured as manual controller with thefollowing system configuration
Single phase
Three phase
Controller can be operated in manual mode even when its configured for AMF mode
₹ 21500 / Piece Get Latest Price
| Voltage | 12V DC |
| Power Rating | 125-250 kVA |
| Current Rating | 250 A |
| Application | DG Set |
| Display Type | LCD |
| Function | Auto Mains Fail, Start Stop |
| Communication Port | RS485, RS232 |
| Supply Voltage | 12 V DC |
| Mounting Type | Door Mount |
| Protection Feature | Under Voltage, Over Voltage, Over Speed, High Temp, Low Oil |
| No. of Inputs | 4 Inputs |
| Country of Origin | Made in India |
| phase | Three PHASE |
| Brand | Cummins |
| Model Name | 0300-6315-01 |
| Usage | Generator |
| IP Rating | IP40 |
Minimum order quantity: 1 Piece
Jatin Shrimal (Manager)
Jatin Sales And Service
Block-A,603, Shanti Deep-2, Nr.Nishan Pride, B/h.Home Town, New Ranip
Ahmedabad - 382470, Gujarat, India